Section 110-222. Criteria required.
site plan criteria required under this chapter shall be as follows:
(1) Plan drawn to scale, no greater than one inch to 50 feet, on sheets two feet by three feet, showing the following site data:
a. Size, height, number of units and location of proposed and existing structures and their relationship to property lines, setbacks, easements, streets, etc.
b. dimensions and total gross acreage of the site and percentage devoted to structures and percentage of parking area devoted to landscaping with curbs and water provisions.
c. Total number of units proposed; total number and size of on-site parking spaces and loading zones.
d. traffic flow diagram to ensure that an orderly and safe traffic flow is permitted within the site and that no traffic problems are created by the proposed ingress and egress routes.
e. Calculation of density (dwelling units per acre).
f. Location and dimension of areas for parks, canals, waterways, boat slips, parking areas, swimming pools, driveways, recreation, trash and garbage pickup, sidewalks, dune crossovers, etc.
g. In those site plans which require a subdivision of land, no site plan shall be approved until the planning and zoning board has given approval to the preliminary plat.
h. The type of enclosure for and location of communal-type trash containers (dumpsters). Type of enclosure shall be subject to approval and acceptance of the planning and zoning board.
i. Fire alarm and standpipe data, when required.
j. Site vicinity map.
k. Location of planned landscaping in compliance with sections 110-566 and 110-567.
(2) topographic survey, including the following:
a. USC and g.s. datum plane.
b. Existing and proposed streetlights, water, sewer, paving, storm drains, fire hydrants, sidewalks, etc.
c. lot lines and dimensions of all setbacks, structures and easements.
d. Location of established seawall line and information for construction, if required.
e. Surveyor's certification.
f. Elevations to be given on one-foot intervals.
g. Range markers and coastal construction setback line, where required.
h. Location and type of existing trees four inches in diameter or larger.
(3) engineering data, including the following:
a. Finished grades for entire parcel, finished elevations for floors, streets, parking lots, sidewalks, ten inches of adjoining property, etc.
b. Details, sections and specifications required of all improvements, such as streetlights, water and sewer (structures, pipes, appurtenances), paving and drainage, curbs, storm drainage and sidewalks.
c. engineer's seal required in drawings.
d. engineering storm drainage design calculation and drainage maps.
(4) square footage of building for the following:
a. Living.
b. parking.
c. Other.
d. Total under roof.
(5) Drawing notes required as follows:
a. Sidewalk and sanitary sewers to be constructed to city standards.
b. Water lines to conform to City of Cocoa standards.
c. Where applicable, fire alarm system to be installed and connected to city fire department standards.
(6) For mean high water, survey shall be done by procedures established by F.S. § 177.25 et seq.